ARTDrive V2 series - Instruction Manual Chapter 5 Quick Start Up Guide • 79
5.4 Keypad Operation
The keypad (Fig. 5.4.1) is made of a LCD display with two 16-digit lines, seven
LEDs and nine function keys. It is used:
- to start and stop the drive (this function can be disabled)
- to increase/decrease speed and jog
- to display the speed, voltage, diagnostics etc. during the operation
- to set parameters and enter commands
The LED module is made of 6 LEDs. It is used to display status and diagnostic
information during the operation. Keypad and LED module can be installed or
removed also while the drive is running.
-Torque +Torque Alarm Enable ZeroSpeed Limit
-Torque Negative torque current
+Torque Positive
Alarm Alarmcondition
Enable Drive enable status
ZeroSpeed Speed <=zerospeed threshold
Limit Actual current >=current limit
torque cu
rrent
This monitoring module can be upgraded with the keypad with
alphanumeric LCD display
Figure 5.4.1: Keypad Figure 5.4.2: LED Module
NOTE! A replacement keypad cable longer than 20 cm must be shielded.
5.4.1 LEDs & Keys
The LEDs present on the keypad are used to quickly diagnose the operating
state of the drive.
Designation Color Function
-Torque yellow the LED is lit when the drive operates with a negative torque
+Torque yellow the LED is lit when the drive operates with a positive torque
ALARM red the LED is lit when the drive signals a trip
ENABLE green the LED is lit when the drive is enabled
Zero speed yellow the LED is lit when motor speed is zero
Limit yellow the LED is lit when the drive operates at a current limit
Shift yellow the LED is lit when the keypad second functions are enabled
ts030g