Do you have a question about the GEFRAN-SIEI ARTDrive Vector V2 Series and is the answer not in the manual?
| Category | Controller |
|---|---|
| Humidity | 5% to 95% non-condensing |
| Series | ARTDrive Vector V2 |
| Control Method | Vector Control |
| Communication Interface | CANopen |
| Protection Features | Overvoltage, undervoltage, overload, short circuit |
| Operating Temperature | -10°C to 50°C |
| Enclosure Rating | IP20 |
| Input Voltage | 200-240VAC, 380-480VAC, 500-690VAC (depending on model) |
Details requirements for connecting the drive to the power supply and proper grounding.
Addresses hazards related to electric shock and potential burns during operation and maintenance.
Warns about risks of fire or explosion in hazardous areas and installation requirements.
Highlights risks associated with improper lifting practices and emphasizes using proper equipment and personnel.
Details requirements for proper grounding and safe electrical connections for drives and motors.
Instructions on how to access the drive connectors by removing covers.
Step-by-step guide for removing terminal covers and cable entry plates.
Provides notes on motor phase connections and checks before enabling the drive.
Details terminal assignments for power sections and recommended cable cross-sections.
Specifies the maximum permissible cable cross-sections for power terminals.
Describes the RV33 regulation card, including LEDs, test points, and jumper settings.
Details the LEDs, test points, and jumper settings for the RV33 regulation card.
Provides a table of plug-in terminal strip assignments for the regulation card.
Explains the potentials of the control section, their isolation, and grounding connections.
Describes the RS 485 serial interface capabilities and connection requirements.
Details the assignment of the plug XS connector for the RS 485 serial interface.
Illustrates typical connection diagrams for ARTDrive.
Provides an example of relay logic using specific command parameters.
Explains features and limits for parallel inverter connections on AC and DC sides.
Details circuit protection measures, including external and internal fuses.
Specifies external fuse types for AC input side connections.
Lists external fuse types for DC input side connections when powered from a common DC bus.
Identifies internal fuses fitted on the drive for protection.
Describes the purpose and operation of braking units for regenerative energy management.
Details the configuration and requirements for the internal braking unit.
Lists technical data and specifications for external standard braking resistors.
Explains the DC Link buffer time and how to extend it with external capacitors.
Describes how the drive handles power dips and the calculation for undervoltage trip time.
Provides minimum times to wait after disconnecting AC input for safe servicing.
Illustrates the functional connection of the drive, motor, and associated components.
Step-by-step guide for configuring the drive and motor parameters for startup.
Guide on how to access, acknowledge, and reset alarms using the keypad.
Provides guidance for correcting specific regulation alarms like External fault and Heatsink OT.
Offers solutions for common issues like motor not turning or turning in the wrong direction.