90 • Chapter 5 Quick Start Up Guide ARTDrive V2 series - Instruction Manual
Tune Analog input 1 gain
C INTERFACE / C01 An Inp 1
Refer to maximum the position of the potentiometer connected to Analog input
1 terminals.
Enter the C01.19 - AI 1 gain tune parameter: "Start…" message will be displayed,
than press [Enter] key to run the procedure.
Wait up to "Autotune End" message will be displayed, than press three time
[Escape] key.
5.6.2 Configuration of the OK Relay
Digital output 0 programming
C INTERFACE / C19 DO config
C19.00 - DO 0 src parameter defines the closing condition of the relay contact
on terminals 80-82.
The "OK relay" can be selected as:
008 - Drive OK
The contact closes when the drive is powered up with no failure alarms
(factory setting).
003 - Drive Ready
The contact closes when the following conditions are fulfilled:
- The drive is powered up
- There are no failure alarms present
- The drive is enabled. The enable operation is defined by
C00.20 - Command select and
C00.21 - En/disable mode parameters
- The magnetizing procedure has been completed. (Drive is ready to deliver
torque)
NOTE! The contact opens immediately on a drive failure, or when the drive is disabled.
To change factory setting from 008 - Drive OK to 003 - Drive Ready:
Enter C19.00 - DO 0 src parameter, scroll up to 003 - Drive Ready selection,
than press [Enter] to confirm the new setting.