ARTDrive V2 series - Instruction Manual Chapter 5 Quick Start Up Guide • 81
5.4.2 Power Up
Power up the drive.
The drive will begin a self test and initialization procedure which will take
approximately 10 seconds. During this period, the display will cycle through
various indications.
During this process, the below message will appear on the display and all LED’s
will simultaneously blink one time:
-Torque +Torque Alarm Enable ZeroSpeed Limit
AC DRIVE
Start up ...
NOTE! During this operation “Drive OK” relay (teminals 80-82 on regulation board) is
not active. The self test and initialization must be complete before the status of
the relay is correct.
After the 10 seconds, the keypad will display the following:
-Torque +Torque Alarm Enable ZeroSpeed Limit
Shift
Jog
Help
Alarm
Escape
Home
Enter
Drive Controls
Navigation
Speed
Press 2 sec.
to disable
R: 0 S: 0
DISPLAY A
Ramp reference
Main menu
Norm speed parameter
Index Main menu
The field indicated by the “R:” is used to show the Ramp reference value (D07.20
- Ramp out mon) once the motor is running.
The field indicated by the “S:” is used to show the motor speed in RPM (A07.00
- Actual speed) once the motor is running.
NOTE! If the drive is connected to a 230V input, the red “Alarm” LED will blink indicating
an UNDERVOLTAGE condition since the drive is factory configured for 400V.
Proceed to the Drive initial setup procedure in section 5.5 for instructions on
completing the configuration and startup.