ARTDrive V2 series - Instruction Manual Chapter 8 Appendix • 345
Chapter 8 - Throubleshooting
8.1 Using Keypad Alarm List
When the red “Alarm” LED blinks, it is indicating one (or more) alarm conditions.
See following steps to reset it:
1) Press [Shift] + [Alarm]
The “Alarm list” will be displayed.
2) Press [Enter]
Press [Enter] one or more times untill “Sequencer” message appears, to
acknowledge the alarms.
NOTE! If the alarm is still active, red LED will blink again. If it not active, red LED will
stop.
3) Press [STOP] key to reset the Sequencer.
R: S:
DISPLAY
Alarm
Alarm list
Spd fbk Loss
Alarm list
Sequencer
Alarm list
<no alarm>
Acknowledged
If still active
If not active the enty
is deleted from the list
Sequencer is reset by
using the “0” key
The Alarm List shows all the occurred alarms, both if they are due to protections
and to errors when limit values are exceeded.
In order to disappear from the alarm list, alarm have to be acknowledged. The
acknowledgement is possible only if the alarm is no longer active. The alarms
are automatically acknowledged after two minutes.
NOTE! Pressing [Enter] will acknowledge the alarm. Acknowledging the alarm will only
remove it from the active alarm list. If the alarm condition also resulted in a drive
trip, the sequence will also need to be reset. This can be done by pressing the
[STOP] key. The drive cannot be re-enabled or started after a trip condition