EasyManua.ls Logo

GEFRAN-SIEI ARTDrive Vector V2 Series - Ereg Param

GEFRAN-SIEI ARTDrive Vector V2 Series
387 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 193
E REG PARAM
According to the chosen regulation mode, some control loops could be inactive.
The following table states (with X) which are the active loops corresponding to each
different mode:
Mode
Speed loop
(Spd)
Current loop
(Curr)
Flux loop
(Flx)
Voltage loop
(Vlt)
V/f *
Sensorless (SLS) XXXX
Field Oriented (FOC) XXXX
tab par E00
Table E00: Control loops settting
* A pseudo-regulator, that is a circuit allowing some of the regulator protective functions,
is active for the current loop with a V/f mode.
As for the manual tuning of the different loops, if required, see chapter 7, Manual
Tunings of Regulator Loops.
The settings of the percentage gains are carried out according to the Basic values stated
inside the specific menu.
E00 REG PARAM / Spd Reg
E00.00 Spd P1 gain % [%] RWS Calc 0.00/100 PP F-S-B Easy 3700
Proportional gain of speed loop.
E00.01 Spd I1 gain % [%] RWS Calc 0.00/100 PP F-S-B Easy 3701
Integral gain of speed loop.
E00.02 Test torque ref [Nm] RWS Calc 0.00/- FK F-S-B Easy 9500
Torque reference applicable during the self-tuning procedure [Nm].
E00.03 SpdReg autotune Easy
Waiting start...
Speed Regulator autotune: enabling command of the data detection phase.
E00.04 Measured Inertia [kgm
2
] RWS 0.00 0.00/Calc FK F-S-B Full 9501
Measured Inertia value of the measured inertia [Kg * m
2
].
E00.05 Measured Frict [Nm] RWS 0.00 0.00/Calc FK F-S-B Full 9502
Measured Frict value of the measured friction [Nm].

Table of Contents