Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 194 ARTDrive V2 series - Instruction Manual
E00.06 Spd P base value [A/rpm] RWS Calc 0.00/Calc FK F-S-B Full 2075
Basic value of the proportional gain of speed loop.
E00.07 Spd I base value [A/rpm/s] RWS Calc 0.00/Calc FK F-S-B Full 2077
Basic value of the proportional gain of speed loop.
E00.08 InUse Spd P gain% [%] R 10 0/100 PV F-S-B Easy 2063
In use value of the Proportional gain.
E00.09 InUse Spd I gain% [%] R 10 0/100 PV F-S-B Easy 2065
In use value of the Integral gain.
E01 REG PARAM / Curr Reg
E01.00 CurrP gain % [%] RWS Calc 0.00/100 PP V-F-S-B Easy 1999
Proportional gain of current loop.
E01.01 CurrI gain % [%] RWS Calc 0.00/100 PP V-F-S-B Easy 2000
Integral gain of current loop.
E01.02 CurrP base value [V/A] RWS Calc 0.00/Calc FK V-F-S-B Full 2005
Basic value of the proportional gain of current loop.
E01.03 CurrI base value [V/A/s] RWS Calc 0.00/Calc FK V-F-S-B Full 2007
Basic value of the integral gain of current loop.
E02 REG PARAM / Flux Reg
NOTE! Menu accessible with Access Level = FULL.
E02.00 Flx P gain % [%] RWS Calc 0/100 PP F-S Full 2013
Proportional gain of flux loop.
E02.01 Flx I gain % [%] RWS Calc 0/100 PP F-S Full 2015
Integral gain of flux loop.
E02.02 Flx P base value [A/Wb] RWS Calc 0.00/Calc FK F-S Full 2021
Basic value of the proportional gain of flux loop.