3.3 Installation Mounting Clearance
NOTE! The dimensions and weights specifed in this manual should be taken into
consideration when the device is mounted. The technical equipment required
(carriage or crane for large weights) should be used. Improper handling and the
use of unsuitable tools may cause damage.
Figure 3.3.1: Max. Angle of Inclination
the maximum angle of inclination is 30°
NOTE! The Drive must b\e mounted in such a way that the free flow of air is ensured.
The clearance to the device must be at least 150 mm (6 inches). A space of at
least 50 mm (2 inches) must be ensured at the front.
On sizes 81600 (AVy...-4, 230...480Vac) and 8200(AVy...-5, 575Vac) the top
and bottom clearance must be at least 380 mm (15 inches), on front and sides
must be ensured a space of at least 140 mm (5.5 inches). Devices that generate
a large amount of heat must not be mounted in the direct vicinity of the frequency
inverter.
Figure 3.3.2: Mounting Clearance
³ 10 mm 0.4"()
[140mm (5.5")]
³ 6"150 mm ( )
[380mm (15")]
³ 2" )50 mm (
[140mm (5.5)]
³ 20 mm ( 0.8" )
[140mm (5.5")]
³ 6"150 mm ( )
[380mm (15")]
³ 10 mm 0.4"()
[140mm (5.5")]
[...] for 81600 and 8200 sizes
NOTE! Fastening screws should be re-tightened after a few days of operation.