346 • Chapter 8 Appendix ARTDrive V2 series - Instruction Manual
unless the drive sequencer is reset.
The drive State Machine, controls the drive running and starting, accounting for
protection & alarming, command sequence, and reset status.
The table below displays various operation states by Sequencer status number:
Sequencer status State
1 Magnetization running
2 Magnetization completed, Stop
3Start
4 Fast stop, Stop
5 Fast stop, Start
9 No alarm, drive is ready to accept all commands
10 Magnetization running and Start command already present
12 Alarm active
16 Alarm not active, waiting for reset
TAV3i020
To read the sequencer status of the State Machine, go to menu:
⎡⎤
R: S:
DISPLAY A
⎣⎦
⎡⎤
DISPLAY A00.00
Output freq A
⎣⎦
up to
⎡⎤
DISPLAY A13
Adv Dsply A
⎣⎦
Press :
⎡⎤
Adv Dsply A13.00
Magnetiz Curr A
⎣⎦
up to
⎡⎤
Adv Dsply A13.07
Sequencer status A
⎣⎦
⎡⎤
Sequencer status
12
⎣⎦