EasyManua.ls Logo

GEFRAN-SIEI ARTDrive Vector V2 Series - Page 203

GEFRAN-SIEI ARTDrive Vector V2 Series
387 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 203
E08 REG PARAM / SLS Fgain
E08.00 Sls mot HPgain [%] RWS 5 0/100 PP S Full 1090
Motor Proportional High gain.
E08.01 Sls mot HIgain [%] RWS 5 0/100 PP S Full 1091
Motor Integral High gain.
E08.02 Sls mot Mpgain [%] RWS 5 0/100 PP S Full 1092
Motor Proportional Medium gain.
E08.03 Sls mot MIgain [%] RWS 0 0/100 PP S Full 1093
Motor Integral Medium gain.
E08.04 Sls mot LPgain [%] RWS 1 0/100 PP S Full 1094
Motor Proportional Low gain.
E08.05 Sls mot LIgain [%] RWS 0 0/100 PP S Full 1095
Motor Integral Low gain.
E08.10 Sls regen HPgain [%] RWS 5 0/100 PP S Full 1101
Regen Proportional High gain.
E08.11 Sls regen HIgain [%] RWS 5 0/100 PP S Full 1102
Regen Integral High gain.
E08.12 Sls regen MPgain [%] RWS 5 0/100 PP S Full 1103
Regen Proportional Medium gain.
E08.13 Sls regen MIgain [%] RWS 0 0/100 PP S Full 1104
Regen Integral Medium gain.
E08.14 Sls regen LPgain [%] RWS 1 0/100 PP S Full 1105
Regen Proportional Low gain.
E08.15 Sls regen LIgain [%] RWS 0 0/100 PP S Full 1106
Regen Integral Low gain.