F05 SPEED REG / Spd droop
F05.00 Droop en src N/A RWS Ipa4000 PList3 PIN F-S-B Full 2470
Ipa 4000 - NULL = Default
It selects the origin of the signal to enable the Speed Droop function.
ªª
ªª
ª
Pick List 3
F05.01 Droop comp src N/A RWS Ipa2510 PList21 PIN F-S-B Full 2475
Ipa 2510 - Droop comp = Default
It selects the origin of the signal of Droop reference function.
ªª
ªª
ª
Pick List 21
F05.10 Droop gain [%] RWS 0.00 0.00/100 PV F-S-B Full 2480
Droop function gain %.
F05.11 Droop filter [msec] RWS 20 Calc/1000 PP F-S-B Full 2490
Filter time constant of Droop function.
F05.12 Droop limit [rpm] RWS 50 0.00/Calc PV F-S-B Full 2500
Droop function allowed correction limit.
F05.13 Droop comp [Nm] RWS 0.00 0.00/…. PV F-S-B Full 2510
Internal value of the Droop reference.
F05.20 Droop out [rpm] R 0.00 0.00/…. PV F-S-B Full 2515
Block output correction.