MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 226 ARTDrive V2 series - Instruction Manual
It select the origin of Moment Inertia signal.
ªª
ªª
ª
Pick List 25
F07.10 Dig Inertia [kgm
2
] RWS 0.00 0.00/Calc PV F-S-B Full 2054
Moment Inertia digital internal value.
F07.11 Dig Friction [Nm] RWS 0.00 0.00/Calc PV F-S-B Full 2052
Friction digital internal value.
F07.12 Inertia cp flt [msec] RWS 30 0/1000 PP F-S-B Full 2590
Inertia compensation filter.
F07.20 I/F cp mon [Nm] R 0.00 0.00/- PV F-S-B Full 2625
Displaying of Inertia Friction compensation signal.