Chapter 6 Parameter • 228 ARTDrive V2 series - Instruction Manual
NOTE! During operation it’s necessary to disable the Speed regulator output.
It is possible to set the Filter time constant on the Speed regulator proportional
part, via G00.13 - Prop filter parameter.
G00 TORQUE / TorqueRef
G00.00 Torque ref 1 src N/A RWS Ipa2430 PList 14 PIN F-S-B Easy 2431
Ipa 2430 - Dig torque ref 1= Default
It select the origin of the signal of Torque reference , to control the Current limit.
ªª
ªª
ª
Pick List 14
G00.01 Torque ref 2 src N/A RWS Ipa2440 PList 15 PIN F-S-B Easy 2441
Ipa 2440 - Dig torque ref 2 = Default
It select the origin of the signal of Torque reference 2 .
ªª
ªª
ª
Pick List 15
G00.02 Torque ref 3 src N/A RWS Ipa2447 PList 44 PIN F-S-B Full 2449
Ipa 2447 - Dig torque ref 3 = Default
It select the origin of the signal of Torque reference 3 , which is adds with Torque
reference 1.
ªª
ªª
ª
Pick List 44
G00.03 SpdTrq mode src N/A RWS Ipa2447 PList 43 PIN F-S-B Easy 2385
Ipa 2390 - Int SpdTrq mode = Default
It select the origin of the signal of Speed Torque mode function, which can be defined
according to the settings of G00.14 - Dig SpdTrq mode parameter; other signals can be
chose through List 43 of Pick List section.
ªª
ªª
ª
Pick List 43
G00.10 Dig frq ref 1 [rpm] RWS 0.00 Calc/Calc PV F-S-B Easy 2430
Digital value of Torque reference 1.
G00.11 Dig frq ref 2 [rpm] RWS 0.00 Calc/Calc PV F-S-B Easy 2440
Digital value of Torque reference 2.