24 • Chapter 2 Inspection Procedure,... ARTDrive V2 series - Instruction Manual
Table 2.3.4.1: Nominal Drive Current
1007 1015 1022 1030 2040 2055 2075 3110 3150 4220 4300 4370 5450 5550 6750 7900 71100 71320 81600
Continuous service, no overload (IEC 146 class 1)
[A]
2.4 4 5.6 7.5 9.6 12.6 17.7 24.8 33 47 63 79 93 114 142 185 210 250 324
Overload service 150%x60s followed by In,min.cycle time 360s (IEC 146 class2)
[A]
2.2 3.6 5.1 6.8 8.7 11.5 16.1 22.5 29.9 42.6 57.1 71.6 84.3 103.4 128.7 167.7 190.4 227 293.8
Overload service 200%x10s followed by In,min.cycle time 30s
[A]
1.6 2.7 3.8 5.1 6.5 8.6 12.0 16.9 22.4 32 42.8 53.7 63.2 77.5 96.6 125.8 142.8 170 220.3
Overload service 200%x60s followed by In,min.cycle time 160s
[A]
1.6 2.7 3.8 5.1 6.5 8.6 12.0 16.9 22.4 32 42.8 53.7 63.2 77.5 96.6 125.8 142.8 170 220.3
Overload service 250%x10s followed by In,min.cycle time 25s
[A]
1.3 2.2 3.0 4.1 5.2 6.8 9.6 13.5 18 25.6 34.3 43 50.6 62 77.2 100.6 114.2 136 176.3
Overload service 300%x10s followed by In,min.cycle time 25s
[A]
1.1 1.8 2.5 3.4 4.3 5.7 8.0 11.2 15 16 21.4 27 31.6 38.8 48.3 63 71.4 85 110.2
Overload service 300%x60s followed by In , min.cycle time 130s
[A]
1.1 1.8 2.5 3.4 4.3 5.7 8.0 11.2 15 16 21.4 27 31.6 38.8 48.3 63 71.4 85 110.2
Continuous service, no overload (IEC 146 class 1) [A] 2.1 3.5 4.9 6.5 8.3 11 15.4 21.6 28.7 40 54 68 81 99 124 160 183 217 282
Overload service 150%x60s followed by I
n
,min.cycle time 360s (IEC 146 class2)
[A] 1.9 3.2 4.4 5.9 7.6 10 14 19.6 26 36.3 49 61.7 73.4 89.8 112.4 145.1 166 196.7 255.7
Overload service 200%x10s followed by I
n
,min.cycle time 30s
[A] 1.4 2.4 3.3 4.4 5.6 7.5 10.5 14.7 19.5 27.2 36.7 46.2 55.1 67.3 84.3 108.8 124.4 147.6 191.8
Overload service 200%x60s followed by I
n
,min.cycle time 160s
[A] 1.4 2.4 3.3 4.4 5.6 7.5 10.5 14.7 19.5 27.2 36.7 46.2 55.1 67.3 84.3 108.8 124.4 147.6 191.8
Overload service 250%x10s followed by I
n
,min.cycle time 25s
[A] 1.1 1.9 2.7 3.5 4.5 6.0 8.4 11.7 15.6 21.8 29.4 37 44 54 67.5 87 99.6 118 153.4
Overload service 300%x10s followed by I
n
,min.cycle time 25s
[A] 0.9 1.6 2.2 2.9 3.8 5.0 7.0 9.8 13 13.6 18.4 23.1 27.5 33.7 42.2 54.4 62.2 73.8 95.9
Overload service 300%x60s followed by I
n
,min.cycle time 130s
[A] 0.9 1.6 2.2 2.9 3.8 5.0 7.0 9.8 13 13.6 18.4 23.1 27.5 33.7 42.2 54.4 62.2 73.8 95.9
2002 2003 2005 3007 3010 3015 3020 4025 4030 4040 5050 5060 5075 6100 7125 7150 8200
Continuous service, no overload (IEC 146 class 1)
[A]
3.8 4.5 7.0 10.8 13.8 18.7 24.2 30 36 46 58 69 86 109 137 158 211
Overload service 150% x 60s followed by In, min.cycle time 360s (IEC 146 class2)
[A]
3.5 4.1 6.4 9.8 12.6 17.0 22.0 27 33 42 53 63 78 99.2 124.7 144 192
Overload service 200% x 10s followed by In, min.cycle time 30s
[A]
2.6 3.1 4.8 7.4 9.5 12.8 16.5 20.3 24.8 31.5 39.8 47.3 58.5 74.1 93.2 107.4 143.5
Overload service 200% x 60s followed by In, min.cycle time 160s
[A]
2.6 3.1 4.8 7.4 9.5 12.8 16.5 20.3 24.8 31.5 39.8 47.3 58.5 74.1 93.2 107.4 143.5
Overload service 250% x 10s followed by In, min.cycle time 25s
[A]
2.1 2.5 3.8 5.9 7.6 10.2 13.2 16.2 19.8 25.2 31.8 37.8 46.8 59.3 74.6 85.9 114.8
Overload service 300% x 10s followed by In, min.cycle time 25s
[A]
1.8 2.1 3.2 4.9 6.3 8.5 11.0 13.5 16.5 21.0 26.5 31.5 39.0 49.4 62.1 71.6 95.6
Overload service 300% x 60s followed by In, min.cycle time 130s
[A]
1.8 2.1 3.2 4.9 6.3 8.5 11.0 13.5 16.5 21.0 26.5 31.5 39.0 49.4 62.1 71.6 95.6
avy2020
-I
2N
Rated output current (@ U
LN
=230-400Vac) :
-I
2N
xK
V
Rated output current (@ U
LN
=460/480Vac) :
AVy-…-4 (230…480Vac)
-I
2N
xK
V
Rated output current (@ U
LN
=575Vac) :
AVy-…-5 (575Vac)