Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 240 ARTDrive V2 series - Instruction Manual
Speed ref
Speed 0 ref thr
DC brake current
0
DC brake
delay
Speed 0 ref dly + Brake close dly
t
1
A
B
DC brake
duration
DC brake state
Output current
DC brake cmd src
A = DC brake delay + DC brake duration > Spd 0 ref dly
B = DC brake delay + DC brake duration < Spd 0 ref dly
Figure I00: DC braking sequence
I00 FUNCTION / DC braking
I00.00 DCbrake cmd src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 1836
Ipa 4000 - NULL = Default
It allows to select the origin of the signal to command DC braking function.
ªª
ªª
ª
Pick List 3
I00.10 DCbrake mode N/A RWSZ 0 0/1 DP V-F-S-B Easy 1832
[0] Off
[1] At Stop
See description above.