MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 244 ARTDrive V2 series - Instruction Manual
AC Mains voltage
100 %
100 %
DC link voltage
PL Timer
Speed ref
Actual speed
Torque current
+100 %
-100 %
Power loss detection
UV level detection
time
Stop
Stop
Stop
Ride through
Ride through
Ride through
Ride through
DC link voltage
PLS Vdc ref
736,307 V
Norm Speed
PLS timeout
10 s
PL deceleration
10000 rpm/s
PL acceleration
100 rpm/s
Speed ref
PLS curr lim
0,896209 A
Figure I00-2: Power Loss Stop