MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 250 ARTDrive V2 series - Instruction Manual
Alarm List and Alarm Recognition
When a new regulation alarm is active, the red led “Alarm” blinks on the display.
By pressing Shift + Alarm it is possible to reach the “Alarm list” page, which lists the
intervened and not yet recognized but also the recognized and still active alarms.
In case a regulation alarm intervenes with Restart=Off (that is without an automatic
restart after the alarm has been reset), also the Sequencer (Statemachine) alarm gets
active.
The alarm recognition can be performed by reaching the “Alarm list”, selecting the alarm
to be recognized and pressing Enter. If the alarm is recognized and inactive, it is
canceled from the list. When all the alarms have been recognized, the red led “Alarm” on
the display il lighted (the Sequencer alarm of the State Machine remains active). The Red
led is lighted till all the alarms become inactive and the user resets the State Machine
(such command can be given, for example, via the keypad with the “red” stop button).
If all the alarms on the drive have been recognized (the red led is lighted) and a new
regulation alarm intervenes, such condition is reported with the blinking of the red led on
the display.
NOTE! It is possible to reset the regulation alarms without recognizing them. In this case
the Drive is active and the Red led blinks (no action in the alarm list has to be
performed).
Alarm Log
This is the historic register Log, stating what happened on the Drive.
It records those Drive alarms considered to be significant. The alarm register is in the
DISPLAY menu. It has 30 entry.
Alarm configurations
In the Alarm config menu it is possible to configure the different alarms (xxx) on the
following points:
xxx activity Activity to be performed in case an alarm occurs
xxx restart Restart enabling
xxx restart time Restart time
xxx hold off Hold off time
Table L22-1: Alarm List table, states the possible settings referring to each alarm type.
Alarm configurations : Activity
With this parameter it is possible to set the action to be performed after the alarm
intervention.
0 => Only msg alarmq Actions: msg
1 => Ignore Actions: none
2 => Disable drive Actions: msg . commands for SM . Status
3 => Stop Actions: msg . commands for SM . Status
4 => Fast stop Actions: msg . commands for SM . Status
5 => Curr limstop Actions: msg . commands for SM . Status
6 => Warning Actions: msg . Status
7 => Not allowed Actions: msg . Status