MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 304 ARTDrive V2 series - Instruction Manual
O06.03 Dancer constant [mm] RWS 1.00 1.0/10000 FK V-F-S-B Full 7363
Measurement of the total material accumulation.
O06.04 Minimum diameter [mm] RWS 1.00 1.0/2000 FK V-F-S-B Full 7364
Value of the winder minimum diameter.
O06.05 DiaClc start src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 7402
Ipa 4000 - NULL = Default
Source of the start Diameter Calculation command.
ªª
ªª
ª
Pick List 3
C06.06 Diameter calc Start ? Full
O06.10 Diameter [mm] RW 1.00 1.00/2000 FK V-F-S-B Full 7365
Calculated diameter.
O06.11 Diacal PI out NULL RW 1.00 -16/16 PP V-F-S-B Full 7366
PI initialization value.
O06.12 DCDelta error [cnt] R 0.00 0.00/... PP V-F-S-B Full 7370
Dancer movement.
O06.13 DCDelta pos NULL R 0.00 0.00/... PP V-F-S-B Full 7371
Winder movement (encoder pulses).