WASH 1 STANDARD
VALUE (type)
TI10 WASH1 SOAK TIME: value 0-10 min
Wash 1 soak time set point. (The time everything is paused)
Only affects the process if PF25 is 1.
1 min (P)
TI11 WASH1 WAITSOAK: value 0-10 min
Wash 1 wait for soak time set point. (The waiting time before everything is
paused)
Only affects the process if PF25 is 1.
1 min (P)
PF17 WASH1 GUARANTEE: value 0.1
Wash 1 temperature guarantee selector. (0= wash 1 time starts directly
whatever temperature achieved, 1= wash 1 time starts at selected wash 1
temperature set point achieved)
1 (P)
RINSE1 STANDARD
VALUE (type)
PF03 RINSE1 SELECTOR value 0.1
Rinse 1 selector (Main parameter for selecting or deselecting the entire
rinse 1.)
0 (P)
CT03 RINSE1 FILLTYPE: value 1, 2, 3, 4, 5 (CW, HW, CW+HW, booster, HCW)
Rinse 1 water type selector (parameter for selecting water to be used in
rinse 1
1=cold water, 2=hot water, 3=mixture of cold and hot water, 4=filling from
booster tank, 5=high quality water).
2 (P)
TI03 RINSE1 TIME: value 0-60 min
Time for rinse 1.
1 min (P)