GETINGE WD15 CLARO
GE15
TECHNICAL MANUAL
6001396902

Table of Contents

Other manuals for Getinge GE15

Questions and Answers

  • S
    Scott DurhamAug 19, 2025
    What to do if the Getinge Laboratory Equipment machine is overfilling?
    • M
      Marvin JohnsonAug 19, 2025
      If the Getinge Laboratory Equipment machine is overfilling, you should: 1. Check the hoses for leaks. 2. Check the drainage system to ensure drainage water doesn't overflow the chamber. 3. Check the function of the level sensor. 4. Check that the water level in the condenser does not increase and form a water lock.
  • J
    jackiealexanderAug 21, 2025
    What to do if there is overfilling in the condenser of Getinge GE15 Laboratory Equipment?
    • S
      steve70Aug 22, 2025
      If there is overfilling in the condenser of the Getinge Laboratory Equipment, you should: 1. Check the function of the condenser’s drainage pump. 2. Check that water can be pumped out of the drainage system. 3. Check the function of the level sensor.
  • R
    Robert HopkinsAug 23, 2025
    What to do if there is an unlocked door on Getinge GE15?
    • N
      nroachAug 23, 2025
      If the door on the Getinge Laboratory Equipment remains unlocked, you should: 1. Check that nothing is trapped in the door. 2. Check that the door locking switch (-S01) is activated on door locking.
  • E
    Elizabeth JordanAug 26, 2025
    What should I do if the Getinge Laboratory Equipment chamber empties slowly?
    • E
      Emily DavisAug 26, 2025
      If the chamber of the Getinge Laboratory Equipment empties slowly: 1. Check the function of the drainage pump. 2. Check the function of the level sensor. 3. Check that water can be pumped out of the drainage system.
  • C
    Casey ChenAug 28, 2025
    What should I do if the Getinge Laboratory Equipment chamber fills slowly?
    • R
      Ronald VillarrealAug 28, 2025
      If the chamber of the Getinge Laboratory Equipment fills slowly: 1. Check that the cover inside the chamber opens for incoming water. 2. Check the function of the level sensors. 3. Check the function of the filling pump for the water softener.
  • T
    Tyler HarringtonAug 30, 2025
    What to do for water leakage in the Getinge GE15 Laboratory Equipment dryer?
    • J
      Jason Flores MDAug 30, 2025
      If you observe water leakage in the dryer of the Getinge Laboratory Equipment, you should: 1. Check the check valves in the drying channels. 2. Check the function of the sensor.
  • B
    Brenda Taylor DDSSep 1, 2025
    What to do if Getinge GE15 Laboratory Equipment shows an incorrect temperature indicator?
    • B
      Brandy BryantSep 1, 2025
      If the Getinge Laboratory Equipment shows an incorrect temperature indicator, check the temperature sensor for an open-circuit or short-circuit.
  • M
    Miss Tammy WilliamsSep 3, 2025
    What to do if Getinge GE15 shows a faulty independent temperature sensor?
    • T
      Teresa WagnerSep 3, 2025
      If the Getinge Laboratory Equipment indicates a faulty independent temperature sensor, check the temperature sensor for an open-circuit or short-circuit.
  • B
    Bradley KrauseSep 5, 2025
    What does it mean if there is high temperature in wash chamber of Getinge Laboratory Equipment?
    • W
      williamrodgersSep 5, 2025
      If there is a high temperature in the wash chamber of the Getinge Laboratory Equipment, it means the temperature in the chamber is more than 5°C above the highest reference point.
  • K
    Katie CamposSep 7, 2025
    What to do if there is low pump pressure in Getinge GE15?
    • S
      Shawn MendozaSep 8, 2025
      If there is low pump pressure in the Getinge Laboratory Equipment, you should: 1. Check that the shut-off valves for the water are open and that water is reaching the machine. 2. Check the function of the sensor.

Summary

PREFACE

SAFETY PRECAUTIONS

PRESENTATION

Control Panel Overview

Details of the machine's control panel, including indicators, buttons, and window displays.

Software Description and Settings

Overview of the machine's control system and configuration options.

MENU TREE

Parameter Settings

Details on adjustable (A) and programmable (P) machine parameters.

ALARM MANAGEMENT

Error Indicators and Troubleshooting

Identification of errors, codes, and step-by-step actions to resolve issues.

PREVENTIVE MAINTENANCE

Periodic Maintenance Schedule

Recommended maintenance activities performed at regular intervals.

FUNCTION CHECK

REPAIRS AND ADJUSTMENT

Program Loading and Management

Procedures for loading system and application programs into flash memory.

Getinge GE15 Specifications

General IconGeneral
BrandGetinge
ModelGE15
CategoryLaboratory Equipment
LanguageEnglish