FC4500-UM-251-9370 98
7 ELECTRICAL SECTION
(9) Press the [Enter] key to display the following menu. (At this time, the pen holder goes down.)
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
+1 24g -1
+10
*****
-10
Target pen pressure
Adjustment value
[F1] key: The adjustment value is increased by 1.
[F2] key: The adjustment value is increased by 10.
[F3] key: The adjustment value is decreased by 1.
[F4] key: The adjustment value is decreased by 10.
(10) Input the factory recorded values for the 24g by using the [F1] through [F4] keys if the Pen Block was
not replaced.
Measure the pen pressure for the 24g with a correx tension gauge if the Pen Block was replaced.
Lift up the pen holder as shown in the picture below, and the measuring point for the pen pressure is
when the bottom of the cutting plunger left from the surface of writing panel.
Increase the adjustment value if the measuring pen pressure is lower than 24g.
Decrease the adjustment value if the measuring pen pressure is higher than 24g.
Adjust the measuring pen pressure to until 24 ± 1 g.
(11) Press the [Enter] key after the pen pressure for the 24 g was adjusted.
The following menu is displayed.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
PEN PRESS SETTING
No.1 -> 210[
g
]
(12) Press the [Enter] key to input the adjustment of value pen pressure for the 210 g in the same way as
described for pen pressure for the 10 g.
Adjust the measuring pen pressure to until 210 ± 10 g if the pen block was replaced.
(13) Press the [Enter] key after the pen pressure for the 210 g was adjusted.
(14) The 400 g pen pressure menu is displayed.