FC4500-UM-251-9370 122
7 ELECTRICAL SECTION
7.10 Adjusting the Home Position
Perform this adjustment when the Main Board or the X home Sensor or Y relay board was replaced.
Conrm the measuring tape is put to the correct position if the measuring tape was replaced.(See section
6.47.)
How to adjust the Home Position
(1) Turn off the power if the power is on.
(2) Set the DIP switch to normal mode.
1
ON
OFF
2 3 4 5 6 7 8
(3) Turn on the power.
(4) Set the Tool condition No.1 to the following setting at the normal mode.
Condition No.1
TOOL Type : PEN
TOOL SPEED: 20
TOOL FORCE: 14
Quality: 1
Assign the TOOL 1 to the Condition No.1.
Select the Condition No.1.
(5) Turn off the power for the plotter.
(6) Set the DIP switch to adjustment mode.
1
ON
OFF
2 3 4 5 6 7 8
(7) Turn on the power.
(8) Press the [Next Page] key until the following menu is displayed.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
HOME ADJ.
PRESS ENTER KEY!!
(9) Press the [Enter] key. The plotter starts to detect the home sensors position.
And then the following menu is displayed.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
MOVE HOME POINT
PRESS ENTER KEY!!
(10) Mount a water-based ber-tip pen to the tool holder 1.