EasyManua.ls Logo

GRAPHTEC FC 4500 Series - 6.26 Front X Belt

GRAPHTEC FC 4500 Series
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FC4500-UM-251-9370 44
6 REPLACEMENT PROCEDURES
6.24 Y Motor
How to detach the Y Motor
(1) Detach the Y Rail Cover (See section 6.3.).
(2) Detach the Rear Y End Cover (See section 6.5.).
(3) Disconnect the Y Flexible Cable from the Y Relay Board.
Y exible Cable
Y Relay Board
(4) Disconnect the X Flexible Cable from the Y Relay Board.
X Flexible Cable
(5) Remove two M3L6 binding head screws holding the Y exible cable bracket on the rear Y bar side
plate, and then detach the Y exible cable bracket with the Y exible cable from the Y rear end plate.
Y Flexible Cable Bracket
M3L6 binding head screw
Y Flexible Cable Bracket