FC4500-UM-251-9370 139
8 TEST MODES
8 TEST MODES
8.1 Printing a List of the Currently Selected Conditions
Caution:
As soon as the F2 (COND. PAT.) key is pressed to select this function in Step (5) below, the pen carriage
begins moving. Be sure to keep hands, hair, and so forth away from the plotter’s moving parts.
The PRINT CONDITION function prints a list of the plotter’s currently selected conditions so you can
check them all at once.
Setting Procedure
(1) Load a medium of A4 size or larger in the plotter.
(2) Press the PAUSE key, then press the NEXT PAGE key until the menu below appears.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
OPTION1 OPTION2
(3) Press the
F4
(OPTION2) key to display the menu below.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
UP HEIGHT POS.OPT
MOVE SPD TEST
(4) Press the
F4
(TEST) key to display the menu below.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
SELF TEST
COND. PAT. DUMP
(5) When the
F2
(COND. PAT.) key is pressed, the menu below appears and the plotter begins printing
a list of its currently selected conditions.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
PRINT CONDITION
(6) After the conditions have been printed, the plotter resumes READY status.