FC4500-UM-251-9370 27
6 REPLACEMENT PROCEDURES
6.15 Operation Panel
How to detach the Operation Panel
(1) Detach the Corner Cover 50L (See section 6.6.).
(2) Loosen the two M3L6 binding head screws holding the left side of Operation Panel.
(3) Remove the two M3L6 binding head screws holding the right side of Operation Panel.
Remove the two M3L6 binding head screws
holding the right side of Operation Panel.
Loosen the two M3L6 binding head screws
holding the left side of Operation Panel.
(4) Slide the Operation Panel to the left, and then detach the Operation Panel from the Operation Tray.
(5) Slide the Operation Panel to the left, and then detach the Operation Panel from the Operation Tray.
Disconnect the Operation Panel cable
from the Operation Panel.
How to install the Operation Panel
(1) Reattach the Operation Panel in the reverse order in which it was detached.