FC4500-UM-251-9370 108
7 ELECTRICAL SECTION
How to adjust the Registration mark sensor position (P.ADJ.+)
(1) Set the DIP switch to normal mode.
1
ON
OFF
2 3 4 5 6 7 8
(2) Turn on the power.
(3) Set the Tool condition No.1 to the following setting at the normal mode.
Condition No.1
TOOL Type : PEN
TOOL SPEED: 20
TOOL FORCE: 14
Quality: 1
Assign the TOOL 1 to the Condition No.1.
Select the Condition No.1.
(4) Turn off the power for the plotter.
(5) Place a copy paper to the lower left corner of writing panel.
(6) Conrm that the surface of printed cross mark target is at. This adjustment will not be done correctly
when the surface of printed cross mark target is touched to the bottom of registration mark sensor
bracket or the printed cross mark target is not loaded to be at.
(7) Mount a water-based ber-tip pen (black color) to the tool holder 1.
(8) Set the DIP switch to adjustment mode.
1
ON
OFF
2 3 4 5 6 7 8
(9) Turn on the power.
(10) Press the [Next Page] key until the following menu is displayed.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
ARMS ADJUST
PRESS ENTER KEY!!
(11) Press the [ENTER] key to display the following menu.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
LEV ADJ DRY TIME
P.AUTO P.MANUAL
(12) Press the [F4] (P.MANUAL)key to display the following menu.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
ADJ.SENS POS
ADJ. ADJ.+