FC4500-UM-251-9370 48
6 REPLACEMENT PROCEDURES
(8) Remove the two M3L8 TP head screw holding the Y Motor, and then detach the Y Motor.
X Motor
M3L8 TP head screw
(9) Loosen the two M4L4 set screws holding the X Motor Pulley, and then detach the X Motor Pulley
from the X Motor.
M4L4 set screw
X Motor Pulley
How to install the X Motor
(1) Reattach the X Motor in the reverse order in which it was detached.
(2) Position the pulley surface and the motor shaft surface to be at.
X Motor Pulley
Position the motor pulley to be at to this side
of motor shaft.