FC4500-UM-251-9370 59
6 REPLACEMENT PROCEDURES
How to install the X Home Sensor
(1) Reattach the X Home Sensor in the reverse order in which it was detached.
(2) Move the Y bar to the far left side, and then conrm the X Home Sensor Dog is not touched to the X
Home sensor. Adjust the X Home Sensor position when the X Home Sensor Dog is touched to the X
Home sensor.
X Home Sensor
X Home Sensor Dog
(3) Perform the Home Position Adjustment when the X Home Sensor is reinstalled (See section 7.10.).