FC4500-UM-251-9370 85
6 REPLACEMENT PROCEDURES
For the FC4500-60 X direction of measuring tape
(1) Cut the top of measuring tape at 3 mm from the 0 position of measuring tape for the X direction of
measuring tape.
(2) Cut the measuring tape at 915 mm position.
Termination 915 mm
For the FC4500-60 Y direction of measuring tape
(1) Cut the top of measuring tape at 3 mm from the 0 position of measuring tape for the Y direction of
measuring tape.
(2) Cut the measuring tape at 615 mm position.
Termination 615 mm
For the FC4510-60 X direction of measuring tape
(1) Cut the top of measuring tape at 3 mm from the 0 position of measuring tape for the X direction of
measuring tape.
(2) Cut the measuring tape at 900 mm position.
Termination 900 mm
For the FC4510-60 Y direction of measuring tape
(1) Cut the top of measuring tape at 3 mm from the 0 position of measuring tape for the Y direction of
measuring tape.
(2) Cut the measuring tape at 620 mm position.
Termination 620 mm