ACO6800+ Installation and Operation Manual 89
Copyright © 2009, Harris Corporation
Chapter 8: ACO6800+ISCST Parameters, LEDs, and Alarms
GPI Input_1 [RO] Displays whether or not GPI Input 1
has been switched to In 1
•N/A
• Switch to A1
GPI Input_2 [RO] Displays whether or not GPI Input 2
has been switched to In 2
•N/A
• Switch to A2
GPI Input_3 [RO] Displays whether or not GPI Input 3
has been switched to Relay Bypass
•N/A
• Relay Bypass
GPI Output_1 [RO] Displays whether or not the output is
set to IN_1
•N/A
• Input IN_1 on line
GPI Output_2 [RO] Displays whether or not the output is
set to IN_2
•N/A
• Input IN_2 on line
GPI Output_3 [RO] Displays whether or not the relay
bypass has been activated
•N/A
• Signal Bypass
Video
LOV Mode 4, 1 Determines the processing mode when
there is a loss of video on the selected
input
• Pass
• Black
• Freeze
Still Image Mode 4, 2 Forces the output to a still image (see
Table 3-10 on page 27 for details)
• Auto
•Force
Still Image Source 4, 3 Selects the source for the still image
• Trouble Slide
• TSG
• None
Test Signal Generator
Pattern
4, 4 Selects the TSG pattern
• Black
• 75% Color Bar
• 100% Color Bar
• H Sweep
• Multiburst
•Ramp
Thumbnail Source 4, 7 Sets the thumbnail source
• In 1
• In 2
• Frame Sync
Video > FS Settings
H Phase 4, A Sets the Frame Sync horizontal phase
Note Available options depend on the
system’s set video standard.
<set video standard>
V Phase 4, B Sets the Frame Sync vertical phase
Note Available options depend on the
system’s set video standard.
<set video standard>
Table 8-2. ACO6800+ISCST SDI Parameters (Continued)
Group Parameter Name
Bank,
Switch
Function Options