A FR6822+ frame must contain a resource module for remote control. Without a resource
module installed, your frame will supply power to the modules. You will be able to control
the modules at the card edge only.
Your frame may have come with one of the following resource modules:
6800+ETH module for controlling and monitoring modules using a CCS network or
web browser
6800+ETHSNMP for controlling and monitoring modules using a CCS network, web
browser, or SNMP-based control application
There are no card-edge controls on resource modules.
Installing a Resource Module
1 Pull out the finger-release screws on the right and left sides of the front panel, and then
open it.
2 Slide the new module into the frame.
3 Locate the slot that corresponds resource module on the left side of the frame, beside the
power supply. (See Figure 2-6 on page 16.)
4 Slide the module into the guides on the frame floor.
The module is properly seated when its edge is flush with the guide edge and the extractor
handle closes. (See Figure 2-10 on page 19.)
5 Close the front panel.
Removing a Resource Module
You may need to remove a resource module if you wish to change the DIP switch settings,
either to set the IP address to default, or to set the module to Fail-Safe mode.
To remove an existing resource module, follow these steps:
1 Pull out the finger-release screws on the right and left sides of the front panel, and then