51
────────────────────────────────────────────────────
4.8 Setting the Printer Output
────────────────────────────────────────────────────
ENTER
Selecting item
▼
▲
Setting on or off
NOTE
Display:
Supplement
Key Key operation
AVE・FREQ
PT・CT・SC
COMP1
COMP2
D/A
INTEG
RANGE SEL
INTERFACE
Moves to each setting screen.
4. Select the item to be printed by using the or key. At this time, unit
symbol and channel on display b and d are flashing to indicates the item.
"on" shown on display d means that the item is printed.
"oFF" shown on display d means that the item is not printed.
5. By pressing the ▲ or ▼ key, on or off setting can be changed.
Repeat this procedure and select "ON" or "OFF" for every items.
6. Press the
ENTER
key, and the flashing will stop and the setting will be
decided.
Unless this operation is done, the internal setting cannot be changed.
If the settings need to be changed again, press either the , , ▲, ▼ keys
and the flashing points will reappear.
・ If all items are set to OFF, the displaying fourth item is printed.
(3) Moves onto the measurement display.
Press the
PRINT
or
EXIT
key. The SHIFT indicator is turned off.
Other keys operations in Printer Setting mode
(SHIFT indicator is lit):