4.10 Setting the Comparator
────────────────────────────────────────────────────
4.10.1 Flowchart
1. Set the table number.
2. Set the comparator item.
3. Set the limit value.
4. Enter the settings.
5. Change the other table.
SHIFT
COMP1
Measurement display
Sets the comparator
COMP1
(or EXIT)
Measurement display
Comparator setting display
For channel 2, press
COMP2
.
4.10.2 Comparator Setting Method
SHIFT
COMP1
Comparator item
Comparator on/off
setting
Measurement value
Limit values
Comparator table
Comparator
channel
4.10 Setting the Comparator
Decides which level the measurement target is on for a given measurement
range.
Turns the comparator function ON/OFF and sets the comparator item and
limit value (table data).
(1) Enter the comparator setting state.
1. Press the
SHIFT
key and the SHIFT indicator is lit.
2. Press the
COMP1
key (for channel 2,
COMP2
).