EasyManua.ls Logo

Hioki 3332 - Page 80

Hioki 3332
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66
────────────────────────────────────────────────────
5.1 Electrical Power Integration and Printer Output Examples
────────────────────────────────────────────────────
RESET
SHIFT
START/STOP
HOLD
RUN HOLD
AV
SC
U
RANGE
15 30 60 150 300 600 SEL AUTO OVER
I
RANGE
1 2 5 ×10 ×100 mA SEL AUTO OVER
SHIFT
INTEG
Hours Minutes Seconds
Integration time
C
ENTER
(1) Reset the integration value. (The RUN and HOLD indicators should be turned
off.)
1. When the RUN indicator is lit, press the
START/STOP
key to stop
integration. The RUN indicator is flashing.
2. Press the
SHIFT→RESET
keys to reset the integration value. The RUN
indicator is turned off
3. Press the
HOLD
key to turn off the HOLD indicator when the HOLD indicator
is lit.
4. When the HOLD indicator is flashing, press the
SHIFT→RESET
keys to turn
off the HOLD indicator.
(2) Set the voltage range to 300 V.
Using the
U
or
U
key, move the flashing to 300 (300 V).
(3) Set the current range to 10 A.
Using the
I
or
I
key, move the flashing to 10 (10 A).
(4) Set the integration time to 1 hour.
1. Press the
SHIFT
key to lit the SHIFT indicator.
2. Press the
INTEG
key to display settings of integration time. The value in the
left end of the display b is flashing.
3. Press the key once to set to "0."
4. Press the key 4 times and the 5th column (a digit for hour) is flashing.
(Pressing the key moves the flashing point in the reverse way.)
5. Press the key once to set to "1."
6. Press
ENTER
key to enter "00001.00.00" (no flashing).

Table of Contents