67
────────────────────────────────────────────────────
5.1 Electrical Power Integration and Printer Output Examples
────────────────────────────────────────────────────
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
SHIFT
PRINT
Print interval Hours Minutes Seconds (10 second step)
Print item
b
ENTER
Selecting item
▼
▲
Setting on or off
ON: +Wh
TIME
C
(5) Set the print interval time to 10 minutes.
1. Press the
PRINT
key during displaying integration setting (If the display is
returned to the measurement display, press
SHIFT→ PRINT
.
2. Press the key 3 times, and the flashing moves to the column of 10
minutes. (Pressing the key moves the flashing point in the reverse way.)
3. Press the ▲ key once to set to "1".
(6) Set the print item of the printer to TIME and +Wh.
1. Press the key 3 times, and "V" is flashing.
2. Press the ▲ or ▼ key to set to "OFF".
3. Press the key to change the item, and then set to ON or OFF by using the
▲ or ▼ key. Set to ON for +Wh and TIME only. (Pressing the key
moves the item in the reverse way.)
4. Press the
ENTER
key, the setting of print interval (10 minutes) and print
item (+Wh, TIME) will be decided.
(7) Set the interface.
Press the
INTERFACE
key during printer setting display.
(If the display is returned to the measurement display, press the
SHIFT
key
and then press the
INTERFACE
key.)
When flashing on display a, set GP-IB and RS-232C by using the ▲ or ▼
key.
Using the GP-IB interface
1. Using the or key, move the flashing to address.
2. Press the ▲ or ▼ key to set to "Pr".