Chapter 10 Specifications
138
Power source • Model Z1005 AC Adapter
Rated supply voltage 100 to 240 V AC
Rated supply frequency 50/60 Hz
Anticipated transient overvoltage 2500 V
• Model 9780 Battery Pack 3.6 V
(Note) The AC Adapter has priority when connected
• The external 12 V DC power source (10 to 16 V DC)
• (Note) Wiring from the external power to instrument should be no
more than 3m long
Maximum rated
power
When using the Z1005 AC adapter: 30 VA (including the AC adapt-
er), 10 VA (HiLogger only)
When using an external 12 V DC power source: 10 VA
When using a 9780 Battery Pack 3 VA
Continuous
operating time
When using the Model 9780 Battery Pack and saving data to a CF
card, approx. 2.5 hours (@25
C)
Charging function With the 9780 Battery Pack installed and the AC Adapter connected
Charging time: Approx. 200 minutes (@25°C)
Note 1. Actual charging time depends on battery condition
Note 2. Charging temperature range: 5 to 30°C
Dimensions Approx. 176W × 101H × 41D mm (sans protrusions)
(6.93"W × 3.98"H × 1.61"D)
Mass Approx. 550g (19.4 oz.) (without Model 9780 Battery Pack)
Approx. 620g (21.9 oz.) (With Model 9780 Battery Pack installed)
Effect of radiated
radio-frequency
electromagnetic field
±5.0%f.s. at 3 V/m
Effect of conducted
radio-frequency
electromagnetic field
±5.0%f.s. at 3 V
Applicable Standards Safety EN61010
EMC EN61326 Class A
EN61000-3-2
EN61000-3-3
Basic Specifications
Display Section
Display character English/ Japanese selectable
Display type 4.3-in TFT Color LCD (480 × 272 dots)
Display resolution Waveform: Max. 20 divisions (time axis) × 10 divisions (voltage ax-
is)
(1 division = 20 dot (time axis) × 20dot (voltage axis))
Note: The number of displayed time axis divisions depends on the
display configuration.
Dot pitch 0.198mm × 0.198mm