13.2 Input Specifications/Output Specifications/Measurement Specifications
207
10
13
Chapter 13 Specifications
(25) High-order harmonic voltage component and high-order harmonic current component (UharmH, IharmH)
Measurement method The waveform obtained by eliminating the fundamental component is calculated using the true
RMS method during 10 cycles (50 Hz), 12 cycles (60 Hz), or 80 cycles (400 Hz) (approx. 200 ms)
of the fundamental wave.
Displayed item High-order harmonic voltage component value:
RMS voltage value for the waveform consisting of components having frequencies of 2 kHz to 80 kHz
High-order harmonic current component value:
RMS current value for the waveform consisting of components having frequencies of 2 kHz to 80 kHz
High-order harmonic voltage component maximum value:
Maximum RMS value for the voltage waveform consisting of components havin
g frequencies of
2 kHz to 80 kHz obtained during the period from EVENT
IN to EVENT OUT (leaving channel infor-
mation)
High-order harmonic current component maximum value:
Maximum RMS value for the current waveform consisting of components having freque
ncies of
2 kHz to 80 kHz obtained during the period from EVENT
IN to EVENT OUT (leaving channel infor-
mation)
High-order harmonic voltage component period:
Period from high-order harmonic voltage component EVENT IN to EVENT OUT
High-order harmonic current component period:
Period from high-order harmonic current component EVENT IN to EVENT OUT
Measurement range High-order harmonic voltage component: 600.00 V
High-order harmonic current component: Varies with the
current sensor used (see input specifica-
tions).
Measurement band 2 kHz (-3 dB) to 80 kHz (-3 dB)
Measurement accuracy High-order harmonic voltage component:
±10% rdg.±0.1% f.s. (specified for 10 V sine wave at 5 kHz, 10 kHz, and 20 kHz)
High-order harmonic current component:
±10% rdg.±
0.2% f.s. + current sensor accuracy (specified as 1% f.s. sine wave at 5 kHz, 10 kHz,
and 20 kHz)
Event threshold High-order harmonic voltage component: 0 V or greater, 600.00 V or less
High-order harmonic current component: 0 A or greater, current range or less
Event IN Start of approx. 200 ms aggregation in which reading was greater than the threshold
Event OUT Start of approx. 200 ms aggregation in which high-order harmonics were not detected during the
first approx. 200 ms aggregation following the IN state
Multiple-phase system treatment Separate by channel
Saved waveforms Event waveforms
High-order harmonic waveform
40 ms from the end of the first approx. 200 ms aggregation interval in w
hich the reading was great-
er than the threshold (8000 data points)