EasyManua.ls Logo

Hioki PQ3198 - Chapter 13 Specifications; General Specifications

Hioki PQ3198
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13.1 General Specifications
191
10
13
Chapter 13 Specifications
Specifications Chapter 13
13.1 General Specifications
Operating environment Indoor use, pollution degree 2, altitude up to 3000 m (9843 ft.)
At an altitude of above 2000 m (6562 ft.), the measurement categories are lowered to 600 V CAT III.
Operating temperature and humidity 0°C to 30°C (32°F to 86°F) 95% RH or less (no condensation)
When charging battery: 10°C to 30°C (50°F to 86°F)
30°C to 50°C (86°F to 122°F) 80% RH or less (no condensation)
When charging battery: 30°C to 35°C (86°F to 95°F)
Storage temperature and humidity -20°C to 30°C (-4°F to 86°F) 95% RH or less (no condensation)
30°C to 50°C (86°F to 122°F) 80% RH or less (no condensation)
(If the instrument will not be used for an extended period of time, remove the battery pack and store
in a cool location [from -20°C to 30°C (-4°F to 86°F)].)
Dust and water resistance IP30 (EN60529)
Standards Safety EN61010
EMC EN61326 Class A
Power supply quality
measurement method
IEC 61000-4-30 Ed2:2008 Class A, IEEE 1159
Power supply Z1002 AC Adapter
Rated supply voltage : 100 V AC to 240 V AC (Voltage fluctuations of
±10% from the rat-
ed supply voltage are taken into account.)
Rated power supply frequency : 50 Hz/60 Hz
Anticipated transient overvoltage: 2500 V
Maximum rated power : 80 VA (When charging, including the AC adapter)
35 VA (When charging, main unit only)
Z1003 Battery Pack
Rated supply voltage : 7.2 V DC
Maximum rated power : 8 VA
Recharge function Charges the battery regardless of whether the instrument is on or off.
Charging time 5 hours 30 minutes at a maximum (at 23°C, as a referential)
Continuous operating time When Z1003 Battery Pack is used (at 23°C, as a referential)
Approx. 3 hours (fully charged, continuous operation, LCD backlight AUTO OFF)
Backup battery Approx. 10 years (at 23°C, as a referential)
For backup clock and setting conditions (Lithium battery)
Maximum recording interval Repeat recording function, 1 week: 55 weeks
Repeat recording function, 1 day: 366 days
Repeat recording function, off: 35 days
Maximum recording events 9999 events (Switchable between 1000 events and 9999 events)
Clock function Auto-calendar, leap-year correcting 24-hour clock
Real-time clock accuracy ±0.3 s per day (instrument on, 23°C±5°C [73°F±9°F])
±1 s per day (instrument on, within operating temperature and humidity range)
±3 s per day (instrument off) (at 23°C, as a referential)
Display refresh rate Approx. 0.5 s
Display 6.5-inch TFT color LCD (640 × 480 dots)
Interface SD memory card, USB, LAN, RS-232C, External I/O
Dimensions Approx. 300W × 211H × 68D mm (11.81W × 8.31H × 2.68D)
Body Strap can be attached.
Mass Approx. 2.5 kg (88.2 oz.) (with Z1003 Battery Pack installed)
Product warranty period 3 years
Accessories See: "Accessories" (p.4)
Options See: "Options" (p.5)
HIOKI PQ3198A961-02