13.2 Input Specifications/Output Specifications/Measurement Specifications
213
10
13
Chapter 13 Specifications
Specified for RMS voltage Urms and RMS current Irms. Current and power values incorporate current sensor accuracy.
-6. Flag concept
IEC61000-4-30 Flagging concept
If an unreliable values are produce during a dip, swell, or interruption, approx
. 200-ms aggregation will be
“flagged.”
An interval data including the flagged 200-ms
aggregation will also be flagged.
Flagged data are referenced to decide the frequency for an interruption, and are recorded in status informa-
tion of the TIME PLOT data. If even
ts of a dip, swell, or interruption are set to off, the values are also flagged.
-5. RMS frequency characteristics
Frequency Voltage Current Power
40 Hz to 70 Hz Specified as RMS value Specified as RMS value
Specified as RMS value
70 Hz to 360 Hz ±1% rdg.±0.2% f.s. ±1% rdg.±0.5% f.s. ±1% rdg.±0.5% f.s.
360 Hz to 440 Hz Specified as RMS value Specified as RMS value
Specified as RMS value
440 Hz to 5 kHz ±5% rdg.±0.2% f.s. ±5% rdg.±0.5% f.s. ±5% rdg.±1% f.s.
5 kHz to 20 kHz ±5% rdg.±0.2% f.s. ±5% rdg.±0.5% f.s. ±5% rdg.±
1% f.s.
20 kHz to 50 kHz ±20% rdg.±0.4% f.s. ±20% rdg.±0.5% f.s.
80 kHz -3 dB -3 dB