101
7.2.2 Preparing the SNTP Configuration
To get an overview of how the time is passed on, draw a network plan with
all the devices participating in SNTP. When planning, bear in mind that
the accuracy of the time depends on the signal runtime.
Figure 26: Example of SNTP cascade
Enable the SNTP function on all devices whose time you want to set using
SNTP.
The SNTP server of the device responds to Unicast requests as soon as
it is enabled.
If no reference clock is available, specify a device as the reference clock
and set its system time as accurately as possible.
Note: For the most accurate system time distribution possible, only use
network components (routers, switches, hubs) which support SNTP in the
signal path between the SNTP server and the SNTP client.
GPS
NTP
Server
ServerClient
Client
Client
Switch
PLC
ServerClient
Switch
ServerClient
Switch
192.168.1.1 192.168.1.2 192.168.1.3
192.168.1.0

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16

Related product manuals