Loading/saving settings
58
3.1
Loading settings
Basic Configuration
Release
6.0
07/2010
3.1.4 Resetting the configuration to the state on
delivery
The device enables you to
X reset the current configuration to the state on delivery. The locally saved
configuration is kept.
X reset the device to the state on delivery. After the next restart, the IP
address is also in the state on delivery.
Setting in the system monitor
Select 5 “Erase main configuration file”
This menu item allows you to reset the device to its state on delivery. The
device saves configurations other than the original one in its Flash
memory in the configuration file *.cfg.
Press the Enter key to delete the configuration file.
Select the
Basics: Load/Save dialog.
Make your selection in the "Delete" frame.
Click "Delete configuration".

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16