Loading/saving settings
Basic Configuration
Release
6.0
07/2010
3.1
Loading settings
55
3.1.1 Loading from the local non-volatile memory
When loading the configuration data locally, the device loads the
configuration data from the local non-volatile memory if no ACA is connected
to the device.
3.1.2 Loading from the AutoConfiguration Adapter
If a ACA is connected to the device, the device automatically loads its
configuration from the ACA during the boot procedure.
The chapter “Saving locally (and on the ACA)“ on page 59 describes how to
save a configuration file on an ACA.
Note: The device allows you to trigger the following events when the
configuration stored on the ACA does not match that in the device:
X an alarm (trap) is sent (see on page 179 “Configuring Traps“),
X the device status is updated (see on page 181 “Monitoring the Device
Status“),
X the status of the signal contacts is updated (see on page 185 “Controlling
the Signal Contact“).
Select the
Basics: Load/Save dialog.
In the "Load" frame, click "from Device".
Click "Restore".
enable Switch to the Privileged EXEC mode.
copy nvram:startup-config
system:running-config
The device loads the configuration data from the
local non-volatile memory.