Operation Diagnosis
Basic Configuration
Release
6.0
07/2010
9.3
Out-of-band Signaling
185
9.3.1 Controlling the Signal Contact
With this mode you can remotely control every signal contact individually.
Application options:
X Simulation of an error as an input for process control monitoring
equipment.
X Remote control of a device via SNMP, such as switching on a camera.
9.3.2 Monitoring the Device Status via the Signal
Contact
The "Device Status" option enables you, like in the operation monitoring, to
monitor the device state (see on page 181 “Monitoring the Device Status“)
via the signal contact.
Select the Diagnostics:Signal Contact 1/2) dialog.
In the "Mode Signal contact" frame, you select the "Manual setting"
mode to switch the contact manually.
Select "Opened" in the "Manual setting" frame to open the contact.
Select "Closed" in the "Manual setting" frame to close the contact.
enable Switch to the Privileged EXEC mode.
configure Switch to the Configuration mode.
signal-contact 1 mode manual Select the manual setting mode for signal contact
1.
signal-contact 1 state open Open signal contact 1.
signal-contact 1 state closed Close signal contact 1.

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16