7.3 Precision Time Protocol
7.3.1 Description of PTP Functions
Precise time management is required for running time-critical applications via
a LAN.
The IEEE 1588 standard with the Precision Time Protocol (PTP) describes a
procedure that assumes one clock is the most accurate and thus enables
precise synchronization of all clocks in a LAN.
This procedure enable the synchronization of the clocks involved to an
accuracy of a few 100 ns. The synchronization messages have virtually no
effect on the network load. PTP uses Multicast communication.
Factors influencing precision are:
X Accuracy of the reference clock
IEEE 1588 classifies clocks according to their accuracy. An algorithm that
measures the accuracy of the clocks available in the network specifies the
most accurate clock as the "Grandmaster" clock.

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16

Related product manuals