Page #107 background image
Synchronizing the System Time in the
Network
Basic Configuration
Release
6.0
07/2010
7.3
Precision Time Protocol
107
X Cable delays; device delays
The communication protocol specified by IEEE 1588 enables delays to be
determined. Formulas for calculating the current time eliminate delays.
X Accuracy of local clocks
The communication protocol specified by IEEE 1588 takes into account
the inaccuracy of local clocks in relation to the reference clock.
Calculation formulas permit the synchronization of the local time, taking
into account the inaccuracy of the local clock in relation to the reference
clock.
PTPv1
Stratum
number
PTPv2
Clock class
Specification
0 – (priority 1 =
0)
For temporary, special purposes, in order to assign a higher
accuracy to one clock than to all other clocks in the network.
1 6 Indicates the reference clock with the highest degree of
accuracy. The clock can be both a boundary clock and an
ordinary clock. Stratum 1/ clock class 6 clocks include GPS
clocks and calibrated atomic clocks. A stratum 1 clock cannot be
synchronized using the PTP from another clock in the PTP
system.
2 6 Indicates the second-choice reference clock.
3 187 Indicates the reference clock that can be synchronized via an
external connection.
4 248 Indicates the reference clock that cannot be synchronized via an
external connection. This is the standard setting for boundary
clocks.
5–254 Reserved.
255 255 Such a clock should never be used as the best master clock.
Table 7: Stratum – classifying the clocks

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16