Loading/saving settings
Basic Configuration
Release
6.0
07/2010
3.2
Saving settings
59
3.2 Saving settings
In the "Save" frame, you have the option to
X save the current configuration on the device
X save the current configuration in binary form in a file under the specified
URL, or as an editable and readable script
X save the current configuration in binary form or as an editable and
readable script on the PC.
3.2.1 Saving locally (and on the ACA)
The device allows you to save the current configuration data in the local non-
volatile memory and the ACA.
Select the
Basics: Load/Save dialog.
In the “Save” frame, click “to Device”.
Click on “Save”.
The device saves the current configuration data in the local non-
volatile memory and, if an ACA is connected, also in the ACA.
enable Switch to the Privileged EXEC mode.
copy system:running-config
nvram:startup-config
The device saves the current configuration data
in the local non-volatile memory and, if an ACA is
connected, also on the ACA.

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16