Synchronizing the System Time in the
Network
Basic Configuration
Release
6.0
07/2010
7.2
SNTP
105
Figure 27: SNTP Dialog
Device 192.168.1.1 192.168.1.2 192.168.1.3
Operation On On On
Server destination address 0.0.0.0 0.0.0.0 0.0.0.0
Server VLAN ID 1 1 1
Send interval 120 120 120
Client external server address 192.168.1.0 192.168.1.1 192.168.1.2
Request interval 30 30 30
Accept Broadcasts No No No
Table 6: Settings for the example (see fig. 26)