26
NOTE
If a large current (such as welding current of a welder) flows from the outside through the frame
ground, the current may also flow around the signal ground, which may damage the printed
circuit board or melt the ground wire.
Therefore, when performing welding work near the IJ Printer, follow the method below regardless of
whether it is in operation.
Cautions on welding
Isolate the frame, print head, and print target detector of the unit from the conveyor and ground, and
make a separate ground connection for the printer. With this method, you can perform welding work
even when the IJ Printer is in operation.
Cautions on welding
Isolate them with any
insulator.
Stand (option)
Print head
Frame of IJ Printer
Primary power cable