EasyManua.ls Logo

Honeywell Galaxy 2 Series - Section 15: Specifications

Honeywell Galaxy 2 Series
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
105
Galaxy 2 Series Installation Manual
Specifications
SECTION 15: SPECIFICATIONS
Table 28. Panel Specifications
Panel Specifications
2-44+ 2-20
Physical
Plastic Box-3 mm polycarb
(with mains transformer and PCB installed)
Width: 300 mm
Height: 250 mm
Depth: 100 mm
Weight: 1.7 kg
Width: 300 mm
Height: 250 mm
Depth: 100 mm
Weight: 1.7 kg
Metal Box-1.2 mm steel
(with mains transformer and PCB installed)
Width: 370 mm
Height: 320 mm
Depth: 85 mm
Weight: 4.5 kg
Width: 400 mm
Height: 255 mm
Depth: 115 mm
Weight: 4.2 kg
Electrical
Panel Current Consumption
PSU Type
Mains Input
Back-up Battery
PSU Max total load
Grade 2 Rating
Max continuous ripple voltage
Individual 12 V outputs:
Bell+12V
Both Aux+combined
Trigger Header+12V
Switched Outputs:
Trigger Header Outputs
Bell Trigger
Strobe Trigger
Trig O utput
Fuses:
Mains
Battery (F1)
Aux (F2)
Bell (F3)
120 mA (max)
A
230 V ac (+10% -15%)
Up to 7.2Ahr 12 V Sealed
Lead-Acid (plastic encl.)
Up to 17Ahr 12 V Sealed
Lead-Acid (metal encl.)
1.4 A (nominal temp. and
mains supply)
1 A
0.5 V at max. load
500 mA max
500 mA max
100 mA max
Can sink 300 mA each
Can sink 500 mA max
Can sink 300 mA each
500 mA, 20 mm anti-surge
(IEC 127)
1 A, 20 mm anti-surge
500 mA, 20 mm anti-surge
500 mA, 20 mm anti-surge
120 mA (max)
A
230 V ac (+10% -15%)
Up to 7.2Ahr 12 V Sealed
Lead-Acid (plastic encl.)
Up to 12Ahr 12 V Sealed
Lead-Acid (metal encl.)
1.0 A (nominal temp. and
mains supply)
600 mA
0.5 V at max. load
500 mA max
500 mA max
100 mA max
Can sink 300 mA each
Can sink 500 mA max
Can sink 300 mA each
200 mA-20 mm anti-surge
(IEC 127)
1 A, 20 mm anti-surge
500 mA, 20 mm anti- surge
500 mA, 20 mm anti- surge

Table of Contents

Other manuals for Honeywell Galaxy 2 Series

Related product manuals