Specifications
SECTION 15: SPECIFICATIONS
Table 28. Panel Specifications
Panel Specifications
2-44+ 2-20
Physical
Plastic Box-3 mm polycarb
(with mains transformer and PCB installed)
Width: 300 mm
Height: 250 mm
Depth: 100 mm
Weight: 1.7 kg
Width: 300 mm
Height: 250 mm
Depth: 100 mm
Weight: 1.7 kg
Metal Box-1.2 mm steel
(with mains transformer and PCB installed)
Width: 370 mm
Height: 320 mm
Depth: 85 mm
Weight: 4.5 kg
Width: 400 mm
Height: 255 mm
Depth: 115 mm
Weight: 4.2 kg
Electrical
Panel Current Consumption
PSU Type
Mains Input
Back-up Battery
PSU Max total load
Grade 2 Rating
Max continuous ripple voltage
Individual 12 V outputs:
Bell+12V
Both Aux+combined
Trigger Header+12V
Switched Outputs:
Trigger Header Outputs
Bell Trigger
Strobe Trigger
Trig O utput
Fuses:
Mains
Battery (F1)
Aux (F2)
Bell (F3)
120 mA (max)
A
230 V ac (+10% -15%)
Up to 7.2Ahr 12 V Sealed
Lead-Acid (plastic encl.)
Up to 17Ahr 12 V Sealed
Lead-Acid (metal encl.)
1.4 A (nominal temp. and
mains supply)
1 A
0.5 V at max. load
500 mA max
500 mA max
100 mA max
Can sink 300 mA each
Can sink 500 mA max
Can sink 300 mA each
500 mA, 20 mm anti-surge
(IEC 127)
1 A, 20 mm anti-surge
500 mA, 20 mm anti-surge
500 mA, 20 mm anti-surge
120 mA (max)
A
230 V ac (+10% -15%)
Up to 7.2Ahr 12 V Sealed
Lead-Acid (plastic encl.)
Up to 12Ahr 12 V Sealed
Lead-Acid (metal encl.)
1.0 A (nominal temp. and
mains supply)
600 mA
0.5 V at max. load
500 mA max
500 mA max
100 mA max
Can sink 300 mA each
Can sink 500 mA max
Can sink 300 mA each
200 mA-20 mm anti-surge
(IEC 127)
1 A, 20 mm anti-surge
500 mA, 20 mm anti- surge