79
Galaxy 2 Series Installation Manual
Option 56 - Comms
The Communications option is used to control the Galaxy 2 Series system signalling and has five submenus
broken down as follows:
1 = Telecoms; 5 = GSM; 6 = HW Priority; 7 = Parameters, 8 = 2-Way Voice
Telecom/GSM
These sub-sections set up the parameters for the built-in dialler modem and the GSM Module. Most of the
programming options are shared between both sections and can be modified from either one, except where
noted.
Figure 31. Telecom/GSM Programming Structure
56 - Comms
1 = Telecom, 5 = GSM
01 = Format
1 = DTMF
(Default)
1 = Channels 1-8
1 = Function
2 = Not used
3 = Not used
4 = Groups
2 = Fixed Reports
2 = SIA
1 = Low Bat Ch9
2 = Invert Open/Close
3 = Send Restores
0 = No
1 = Yes (Default)
0 = No (Default)
1 = Yes
0 = On Unset (Default)
2 = Sys Restore
1 = Triggers (see Trigger Events table)
3 = Contact ID
1 = Triggers (see Trigger Events table)
02 = Telephone No. 1
03 = Account No. 6 digits Max.
04 = Receiver
1 = Alternate (Default)
2 = Dual
20 digits Max
05 = Telephone No. 2
20 digits Max
06 = Dial Type
(PSTN only)
1 = Tone (Default)
2 = Pulse
07 = Autotest
1 = Intervals
0 - 99 hours (Default = 24 Hrs)
08 = Engineer Test
09 = No. of Rings
00-15 (Default = 15) 15 = Ans Mach defeat
10 = Line Fail
0 = No
1 = Yes
1 = Debounce Time (Default = 60 seconds)
12 = Remote Access
1 = Access Period
3 = Callback No.
17 = SMS Paging
1 = Mobile Nos.
4 = Downloader ID (8 digit password)
1 = Mobile No.
2 = Event Type (see SMS Event Type table )
3 = Group Map
2 = Centre No. (separate for GSM and PSTN)
3 = Format
1 = TAP (Default)
2 = UCP (SMS)
3 = UCP (Numeric)
4 = Site ID (16 character text)
Telephone No.
1 = Mobile 1
2 = Mobile 2
As per Mobile 1
3 = Mobile 3
As per Mobile 1
0 = Full (Default)
1 = When Unset
2 = No Unsetting
11 = Fail to Comm 0 - 244 seconds (Default = 120)
5 = UCP Operation
1 = Call Input
2 = Call Input Sup
3 = SMS Message
SIA Level 0 (0-3)
2 = Access Mode
1 = Direct Access
2 = Manager Authorise

Table of Contents